- How to Connect Your Wood Stove Fan to Central Heating Ducts | Home Guides | SF Gate
- Related Forums
- How to Connect Your Wood Stove Fan to Central Heating Ducts
- Recent Questions and Replies
- Linking indoor woodstove furnace to existing gas furnace ductwork.
Anyways just thought i'd say what i was thinking. Thanks to both of yas. We got our trailer for free, and I figure it's worth a few hundred dollars at the most, so we don't have it insured The furnace seems to be a safe distance away from the trailer, though. We never have sparks flying. At the worst, a charred log might drop out the furnace door onto bare dirt, but that goes out quickly and is far from the trailer. How to install an exterior wood furnace.
Comment by Everett — Mon Feb 23 Comment by anna — Mon Feb 23 Comment by Dav — Sun Jul 12 It's great to meet you, Dav! I'm glad our DIY posts hit the mark we're always hoping that other people can learn from our mistakes. We look forward to hearing more about your adventures.
How to Connect Your Wood Stove Fan to Central Heating Ducts | Home Guides | SF Gate
Comment by anna — Sun Jul 12 What does your insurance company say about the stove so close to the trailer? Comment by Anonymous — Wed Nov 11 Comment by anna — Wed Nov 11 Okay, so heat from the enclosed fire is circulated into mobile home and existing ducts bring colder air back, but how are smoke and fumes from the fire exhausted? I know I'm missing something here but I'm old Paul There's a chimney that comes out the back of the exterior wood furnace, where there's no sleeve for air flow. The smoke goes up that chimney just like in a normal wood stove. Comment by anna — Sun Feb 16 I worked on a similar setup a few years ago, the only difference was that, I rigged up the furnace to a radiator, the radiator had water circulating through it which supplied heat to the rest of the house.
By the way, there was a large fan on the radiator that blew hot air around the living space, both the water and the fan worked on the same pump, and the pump was operated by the rising heat from the furnace, talk about maximum efficiency;-. Comment by Eric Blaise — Fri May 29 It's expensive and somewhat complicated to tie into existing ductwork due to the backdraft dampers required. I looked into tying into my existing HVAC at first, but the cost was ridiculous to do so, I was far better off running dedicated heat and return ducts for my Fahrenheit pellet furnace.
I posted a thread with photos of how I installed my own duct work for my Fahrenheit unit, it was not difficult to do.
Related Forums
Just make sure you follow manufacturer's specs on minimum duct size, etc. I ended up branching a main 10" heat duct into two 8" ducts and installed two 12x20" heat registers in my great room. Complicated HVAC calculations based on cfm are required for determining how to properly install a duct system. I installed a return on the opposite side of my great room to encourage a nice, convective airflow through my large great room. The furnace supplies enough heat to warm my entire sq.
Then trying to sue the stove Mfg. The reason the stove manufacturers don't want any connections to duct work is to protect the masses of idiots out there. I think its only through innovative tinkering that the next product gets developed. The pellet stove makers seem like a pretty conservative bunch. Look into coal stoves if you want to see a group of back room tinkerers, stoves with full heat jackets, removing blowers to rooms below the stove for quieter stoves, the list goes on and on.
Check out the coal stove makers web sites, they can be custom ordered with ducting and blowers, and coal stoves put out 90k, k plus BTU's.
- black south african dating;
- What is the correct way to tie a stove into your ductwork?.
- Ducting an add on wood furnace.
- How to install an exterior wood furnace?
- free dating site like pof?
- Your Answer.
I see nothing wrong with a little yankee ingenuity. Sometimes they write the manuals for more than just idiots. They write it taking into account failure modes. In a perfect designed system with duct work it may work fine. What happens when a blower bearing seizes?
How to Connect Your Wood Stove Fan to Central Heating Ducts
Does the stove shutdown before any duct related damage can occur? Always do "what ifs" on different worst case conditions. They may happen rarely, but all it takes is once to occur with the worst case conditions and stuff goes bad. I like the idea of a pellet furnace with dedicated ductwork. Though this becomes less practical if your basement ceiling is finished.
IMHO, I had a better chance of burning my house down with the smoke dragon I used before the pellet stove. How many over fire safetys do wood stoves have? You boys need to look at the stoves that do have ducting allowed and see if there are any safeties or Precautions added. They only have one thing that stands out.
Same as a pellet furnace. And a small feature I added to mine. Sealed convection path to the blower. Hanging duct in front may have draw backs. Smoke and dust can enter the venting with it hanging in front of the stove. A sealed path will reduce this. Yes I agree that going with a furnace to duct the heat to where you need it is the best route. But until someone can point me to a safety feature I missed. My duct stays connected! The thing that makes them work is more cfms to reduce the temperature and also the proper size pipe.
You did the mods to make yours function correctly.
I agree about the over-fire with the wood stove furnaces that I see for sale. Just a loss of electricity can cause a problem and that is the biggest concern I have.
Recent Questions and Replies
Pellet stoves don't have that problem. A run away fire will get shutdown by the temperature over limit. You have almost CFM in your stove now, pretty close to a furnace size blower. My Fahrenheit only has Pellet Furnace. My Quad freestanding is CFM. Smaller blower, more heat output.
So you have more than double, almost triple the CFM than any ordinary "Freestanding" pellet stove. Your wood unit does not. Mar 9, Messages: I have that same furnace I used 8" black stove pipe for the first 5' coming off the furnace then regular duct work with a one way butterfly damper in it to my homes furnace.
Do not run your house furnace blower this will fight the Englander's blower and could over heat the furnace, you do not need to do anything with your return side of your duct work, the englander will pull air from the room its in. Been running it this way for 3 years with no problem this way is also per Englander's installation specs.
Linking indoor woodstove furnace to existing gas furnace ductwork.
My run of duct work is approx. So at a 60' ft run you will loose a little umph but I think you should be ok. The damper and other supplies including installation guide for your stove can be found at Englanders website. You must log in or sign up to reply here. Share This Page Tweet.